HZD-Z-6A-A2-B2-C2-D2 series
HZD-Z-6A/HZD-Z-7A is an upgraded version of the HZD-Z-6/HZD-Z-7 shaft vibration transmitter. The upgraded transmitter has added a digital display function, making monitoring data more intuitive. In addition, it uses a thin film button switch, making parameter settings and other operations more convenient.
The HZD-Z-6A/HZD-Z-7A shaft vibration transmitter is mainly used to monitor the radial vibration of rotors, measure rotating machinery, and output analog current and alarm shutdown signals. It can be easily connected to DCS and PLC systems.
Fault monitoring: monitoring the radial vibration, measurable shaft vibration, and runout of rotating machinery; Monitor the increase in vibration caused by rotor imbalance, misalignment, and loose components;
Measurement parameters: radial vibration;
Unit type: various rotating machinery such as steam turbines, fans, compressors, pumps, etc; Suitable for retrofitting old units;
Installation requirements: Generally, it is required to install a set of X and Y probes with a 90 ℃ interval near the bearing. For standard double bearing rotating machinery, four sets of transmitters are usually configured.
Note 1
The HZD-Z-6A integrated shaft vibration transmitter only needs to be used in conjunction with the probe and extension cable, and has all the functions of a split type, eliminating the need for a preamplifier and further reducing the number of measuring components, greatly improving its accessibility
The HZD-Z-7A shaft vibration transmitter requires a preamplifier, probe, and extension cable to form a system
Technical indicators·
Working power supply: 24VDC ± 10%·
Input signal: Accept eddy current sensor signal, sensitivity 8.0V/mm, range: 0~500um (peak to peak)·
Display: Display mode: Four digit 0.28-inch LED digital display
LED displays OK green, ALERT, DANGER (alarm, danger) red·
Current output: 4~20mA, output load ≤ 500 Ω
Measurement error:<1% of full scale·
Alarm point setting: 0-100% full range, accuracy ± 1%·
Relay sealing: epoxy resin, node capacity DC 30V/5A or AC220V/5A, single pole double throw
Alarm reset mode: manual or automatic reset
Buffer output: 8.0V/mm raw signal output, output impedance 1K Ω
Temperature range: During operation: 0 ℃~+65 ℃; Storage time: -30 ℃~+80
Relative temperature: up to 95% non condensing
Dimensions: 90x 120 × 75mm
Installation method: rail installation or on-site installation
Guide rail installation: 35mm standard guide rail on-site installation size: 90 × 80mm·
Weight: Approximately 660g
Please fill out following form and we will get back to you.